Start with the medium: is it fouling, abrasive, corrosive, cryogenic or hydrogen? This drives geometry, materials and coating.

Define the envelope: temperature min/max, pressure class, size, and required shut-off leakage class. Add cycling frequency and actuation / failure mode.

Finally, list compliance and documentation: design standards, fugitive-emission class, fire-safe, NACE, and the certificate pack you need. With these inputs, an application engineer can size and configure the right valve.